– 00A163 No Bus Rest, in spite of disconnection 30U and 30G
Rolls-Royce Phantom : Closed-Circuit Current High about 12A when the key is removed and the Car doesn’t go to sleep mode so the Battery drains fast and exhausted
00A158 Closed-Circuit Current
00A163 No Bus Rest
Try to remove the fuse below …. and see the changing of the 30U Terminal Current:
This content is for Free, Deluxe, and Premium members only. Please subscribe to read more ! Subscribe
Terminal R is correct in the Safety and Gateway Module
So the problem of fault code : 00A158 Closed-Circuit Current and 00A163 No Bus Rest is because of shorting the supply wire from CAS to the Right B-Pillar Satellite Module.
Supply wire from CAS to Right B-Pillar Satellite Modulethe position of shorting pointClosed-Circuit Current when Sleeping 40 mA is OK
After repairing the damaged wire, everything comes back normally.
Below is the Troubleshooting Chart for Energy Diagnostic, this will help figure out the problem quickly and exactly :